+86-21-66580701      joycewang@toprise.com.cn
Home » Products » Smoke Vent » Max Automatic Smoke Vent for Basement

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

Max Automatic Smoke Vent for Basement

Availability:
Quantity:

1.downLoadImg

1676356186631


30° Triangle:

 Ideal for regions in the south that experience more rainfall and can quickly change the direction of flow. 

Designed for small to medium-sized openings (spanning 2 meters or less).

Has a load capacity of 700Pa.


Arched type: 

Perfect for areas in the north with heavier snowfall. 

Suitable for larger openings (spanning over 2 meters). 

Boasts a strong load capacity of at least 1000Pa.


Flat slope type: 

Suited for areas with less rain and snow. 

Ideal for smaller openings (spanning less than 2 meters).

 Has a load capacity of 500Pa.

ADVANTAGE

The fully welded thermal break and heat insulated aluminum alloy frame effectively prevents rainwater from entering the room at different angles. 

The inner frame, made of thermal break aluminum alloy, effectively prevents the reverse flow of rainwater and stops it from pouring back into the room. 

The EPDM sealing strip prevents the skylight sheet from being rigidly connected to the window frame, allowing for expansion and contraction during temperature changes. This enhances water tightness, air tightness, and extends the lifespan of the skylight.

.

16855180726891685518091981

Rainwater can be easily drained away. 

The internal structure is constructed with a thermal break aluminum alloy, which effectively prevents rainwater from flowing back and entering the room. 

If the skylight panel gets damaged or broken, it is simple to replace.

1685518122546

The unique frame design, combined with a concealed hinge, safeguards the hinge against corrosion caused by the environment. This ensures a longer lifespan and stability for the hinge.

The patented frame profile, in conjunction with the hidden hinge, eliminates the need for any openings in the window frames, preventing water leakage.


1685518136568



天瑞详情页_21
Using Guide of Max Automatic Smoke Vent for Basement:

The Max Automatic Smoke Vent for Basement is a crucial safety feature designed to provide smoke ventilation in the event of a fire. Here is a guide on how to use it effectively:

1. Familiarize Yourself with the System:
  Before using the Max Automatic Smoke Vent, it is essential to understand its components and operation. Read the manufacturer's instructions and familiarize yourself with the control panel, sensors, and any other features specific to the system.

2. Install and Position the Smoke Vent:
  Ensure that the smoke vent is correctly installed in the designated area of the basement. Follow the manufacturer's guidelines for proper installation, including any necessary electrical connections and mounting instructions. Position the vent in a location that allows for effective smoke extraction.

3. Connect Power and Control:
  Connect the smoke vent to a reliable power source as per the manufacturer's instructions. Ensure that the control panel is properly connected and functioning. If the system includes any backup power options, ensure they are properly set up and functional.

4. Set Up the Smoke Detection System:
  The Max Automatic Smoke Vent is typically equipped with a smoke detection system. Ensure that the smoke detectors are properly installed and connected to the control panel. Test the detectors regularly to ensure they are functioning correctly.

5. Test the System:
  Regularly test the Max Automatic Smoke Vent to ensure it is in proper working condition. Follow the manufacturer's guidelines for testing procedures. Conduct both manual and automatic tests to verify the system's functionality.

6. Understand Alarm Signals:
  Familiarize yourself with the different alarm signals of the Max Automatic Smoke Vent. Understand the meaning of each alarm signal and how to respond appropriately in case of an emergency.

7. Regular Maintenance:
  Perform regular maintenance on the smoke vent system. Keep the vent clean and free from any obstructions that may hinder its operation. Inspect the system for any signs of damage or wear and address any issues promptly.

8. Educate Occupants:
  Educate the occupants of the basement about the Max Automatic Smoke Vent system. Provide clear instructions on what to do in case of a fire, including evacuation procedures and how to respond to alarm signals.

Remember, it is crucial to consult the manufacturer's instructions and guidelines specific to the Max Automatic Smoke Vent for Basement you are using. Following these guidelines will help ensure the effective operation of the system and enhance safety in the event of a fire.


Introduction
Previous: 
Next: 

Product Category

Contact us
Contact us

QUICK LINKS

PRODUCTS

CONTACT US

  +86-21-66580701 / +86-13681692579
  +86-13681692579
  toniwang52
  No.2, Binyang Road, Taicang Port Development Zone, Jiangsu, China
Copyright © 2021 TOPRISE . All rights reserved. Sitemap  Support By Leadong