TOPRISE provides natural ridge ventilators and slope ventilators. It operates through natural wind and indoor and outdoor temperature differences. It can provide Dwifungsi of skylight and ventilation. The damper can be opened or closed.
Roof ridge ventilator is a large-scale comprehensive equipment that integrates ventilation, exhaust, and lighting. It consists of pressed color steel plates, fiberglass sheets, steel structural frames, and other related components. Roof ventilators have been applied in various industries such as electricity, metallurgy, chemistry, electricity, shipbuilding, and other buildings.
TOPRISE-M-14 (with or without damper) | Throat Width (mm) | Throat Length (mm) | Exhaust Area (m²) | Motor Power (kw/m) |
600 | 1200xn, 1500xn (used in metal roof or concrete roof) | 0.30 | 0.12 |
800 | 0.35 | 0.12 |
900 | 0.40 | 0.12 |
1200 | 0.50 | 0.12 |
CHARACTERS
1. The roof ventilator is composed of a main skeleton and a secondary skeleton.
It is easy to deliver and install.
2. The main skeleton and auxiliary skeleton are welded in our factory, sturdy and stable.
3. The main skeleton is welded together with the foundation steel of the throat of the ridge ventilator, making it a part of the roof
4. The side panels are made of pressed color steel plates, and the edges are made of curved color steel plates.
5. The rainproof board is made of high-quality fiberglass panels, which have functions such as lighting, smoke exhaust, and ventilation
6. Set up deflectors to avoid indoor rainy and snowy weather.
7. Install a gutter in the ridge ventilator, where rainwater can flow onto the roof to avoid noise and flooding.
APPLICATION
(3 degrees Celsius temperature variation, 5 degrees Celsius temperature difference) Factory or warehouse that does not emit significant hot gas: recommended air change rate is 6-10 times per hour.
(3 degrees Celsius temperature variation, 5 degrees Celsius temperature difference) Factory that emits minimal hot gas or smoke: recommended air change rate is 10-20 times per hour.
(10 degrees Celsius temperature variation, 15 degrees Celsius temperature difference) Factory that emits moderate amounts of hot gas or smoke: recommended air change rate is 20-30 times per hour.
(Temperature difference of 15 degrees Celsius) Factory that emits a substantial amount of hot gas or smoke: recommended air change rate is 30-35 times per hour.
Q: Could you customize the size?
A: We have standard throat width. We can customize the length.
Q: What's your MOQ?
A: 100 meters.
Q: Could you recommend the model and quantity?
A: Yes, we can design the model and quantity as per the warehouse dimension and warehouse type.
Q:How about the lead time?
A: Normally 2-3 weeks. It depends on the quantity and our production plan.